Overview

DFS is a test set with a built-in database of fault voltage and current waveforms that simulate every fault a protective relay may encounter in service, and it automatically replays these faults to the relay. DFS generates the signals for protective relay characteristic tests and automatically analyzes how the relay responds. Using the IEC 61850 protocol, DFS analyzes the data produced by relays during actual operation.
Field-tested by Korea Hydro & Nuclear Power / Validated at the KEPCO Research Institute's protective relay test center
- ABBSIEMENSSELGE Digital protective relays
- Operation analysis IEC 61850 (international standard)
- Report generation
- Automatic fault data conversion
- Voltage/current injection
Why It Matters
Errors occur despite costly engineering for reliability verification
- Protective relays guard a wide variety of power equipment, and the systems in which they are installed are complex
- Even with a well-designed system, carefully calculated settings and reliability testing, hidden errors that slip through pre-commissioning tests can cause relays to misoperate or fail to operate, escalating damage
- Protective relays must be 100% reliable before going into service, so these errors must be eliminated in advance
- Utilities therefore pay engineering costs several times the price of the relays to verify reliability and build a flawless protection system — yet errors still occur
- Damage from relay misoperation or failure during equipment faults can range from hundreds of millions to hundreds of billions of won
- This is because conventional reliability tests only check whether relays operate as configured, rather than simulating real fault conditions
Key Advantages
Automatic fault waveform conversion
- Normally, the system must be modeled for each relay's installation whenever equipment changes. DFS automatically converts a recorded fault waveform to match each relay's environment, so it can be applied to any system
Automatic control of relay test sets
- Controls voltage and current sources through a single interface to replay relay faults, providing a consistent test environment
Operation analysis and judgment via IEC 61850
- Uses the IEC 61850 protocol to check relay operation over the network in real time and provides reports on test results and operations
Key Features

Replaying contingency faults on protective relays
- Analysis of fault waveforms in COMTRADE format
- Automatic conversion of simulated waveform data to system characteristics
- Playback of simulated waveforms optimized for the measurement environment
Automatic generation of simulated waveforms from system characteristics
- COMTRADE fault waveform analysis
- Automatic conversion of voltage/current data to system characteristics
- Test data optimized for the measurement environment
Root-cause analysis of relay operation
- Analyzes actual relay operation data via IEC 61850 when reviewing simulation results
- Automatically diagnoses fault causes, countermeasures, actions taken and relay operations
- Lets users view voltage and current waveforms before and after relay operation
Generation and delivery of relay operation analysis results
- Generates test analysis results and keeps their history
- Generates test reports with automation tools
Expected Benefits
Ensuring protective relay reliability
More advanced relay reliability verification
- Automatically converts fault waveforms to each relay's installation environment, so it works with any system
- Verifies data through simulation before applying signals to the live system
- Ensures reliable operation for every fault that can occur in protection equipment
Greater operational efficiency
- Minimizes unnecessary engineering to improve equipment operating efficiency
- An intuitive interface lets even less experienced staff operate the test set
- Standardized tests and a portable design make operation easy
- Fast situational judgment and test tracking without dedicated experts
Lower economic losses
- Cuts the repeated time and labor costs of simulating diverse, complex equipment
- Reduces the cost of outside specialists and subcontractors
- Reduces losses from relay misoperation or failure to operate
Specifications
Interoperability and compliance with international standards
- Supported equipment
- ABB protective relays for generators, motors and transformers
- GE protective relays for generators, motors and transformers
- SIEMENS protective relays for generators, motors and transformers
- SEL protective relays for generators, motors and transformers
- Supported protocols
- IEC61850
- System operation
- Runs without installing any agent on the protective relays
- Detects faults in real time when relays operate and analyzes causes automatically
- Works in environments that mix relays from different manufacturers